CXDM-E2 Remote Distribution Panel

Distribution Systems
  • Product Line: Distribution
CXDM-E2 Remote Distribution Panel
  • High density remote distribution panel for Telecom CO’s, MSC’s, Data Center and Cable Headend facilities
  • Industry leading system density
  • High Breaker Density - 11x plug-in bullet breakers or TPS/TLS fuses per bus (22 position per 19" panel)
  • High Current Density - Each bus is rated for a maximum amperage of 600A
  • ‘Split bus’ design provides redundant input feeds to network equipment
  • 2RU height recovers space in network bays for revenue generating equipment
  • General Information


    Alpha’s E2 panel is a high density breaker panel used in Telecom Central Offices, cable headends and datacenters for tertiary distribution applications. The 2RU panel designed with a split bus, offers the capability for upto 22 plug-in breaker/ fuse positions in a 19” configuration. Individual 600A buses allow for maximum utilization of distribution capacity.

    The E2 offers options for remote monitoring of alarms and analog parameters via a CAN bus to a centralized controller (CXC-HP) or with IP/SNMP connectivity.
    • Ordering Information
      S.No Part Number Panel Description
      1 0917001-001 (-101) CXDM-E2, 19/23", 2RU, -48V, 600A Per Bus, 11A/11B Load Breakers, Indicator Board
      2 0917001-002 (-102) CXDM-E2, 19/23", 2RU, -48V, 600A Per Bus, 11A/11B Load Breakers, CAN Conn.
      3 0917001-003 (-103) CXDM-E2, 19/23", 2RU, -48V, 600A Per Bus, 11A/11B Load Breakers, IP/SNMP Conn.
      Note: (-101, -102, -103 include kit #0370297-001 for vertical input connections)
      Nominal Specifications
      Panel Part Number 0917001-001 0917001-002 0917001-003
      Electrical
      Nominal voltage +/-24V (or) +/-48V +/-24V (or) +/-48V +/-24V (or) +/-48V
      Bus Capacity 600A per Bus 600A per Bus 600A per Bus

      Mechanical
      Dimensions 3.5"H x 19"W x 12"D 3.5"H x 19"W x 12"D 3.5"H x 19"W x 12"D
      Mounting Flush/Center Flush/Center Flush/Center
      Weight      

      Connections
      Input (Hot and Return) ⅜" Holes on 1" Center* ⅜" Holes on 1" Center* ⅜" Holes on 1" Center*
      Positions 11x sets load breakers per bus
      (22 positions per panel)
      11x sets load breakers per bus
      (22 positions per panel)
      11x sets load breakers per bus
      (22 positions per panel)
      Output (Hot and Return) 22x sets of ¼" studs on ⅝" Centers 22x sets of ¼" studs on ⅝" Centers 22x sets of ¼" studs on ⅝" Centers
      Output (Hot and Return) Double Pole: ⅜" Studs on 1” Centers**
      Triple Pole: ⅜" Studs on 1” Centers***
      Double Pole: ⅜" Studs on 1” Centers**
      Triple Pole: ⅜" Studs on 1” Centers***
      Double Pole: ⅜" Studs on 1” Centers**
      Triple Pole: ⅜" Studs on 1” Centers***
      Chassis ground ¼" studs on ⅝" Center ¼" studs on ⅝" Center ¼" studs on ⅝" Center

      Controls
      Alarms Breaker/Fuse trip: Form C contacts Breaker/Fuse trip: Form C contacts Breaker/Fuse trip: Form C contacts
      Monitor Breaker/Fuse trip via Form C Contacts Breaker/Fuse trip and bus voltages via
      CAN bus to CXC-HP controller
      Breaker/Fuse trip and bus voltages on CXC-HP controller (IP/SNMP)
      LED indicators System Ok (Green) Breaker/Fuse Trip (Red) System Ok (Green) Breaker/Fuse Trip (Red) System Ok (Green) Breaker/Fuse Trip (Red)

      Environmental
      Temprature 0 to 40°C (0 to 104°F) 0 to 40°C (0 to 104°F) 0 to 40°C (0 to 104°F)
      Humidity 0-95% non-condensing 0-95% non-condensing 0-95% non-condensing

      Compliance
      Safety CSA C22.2 No. 609050-1-03 CSA C22.2 No. 609050-1-03 CSA C22.2 No. 609050-1-03